Specification Product :
Single Phase (VXm 8/50)
Power :
KW : 0.55
HP : 0.75
Flow Rate (Q) = m3/h : Total manometric head = metres
0 : 6
3 : 5.5
6 : 5
9 : 4.4
12 : 3.6
15 : 2.8
18 : 2
21 : 1
Flow Rate (Q) = l/min : Total manometric head = metres
0 : 6
50 : 5.5
100 : 5
150 : 4.4
200 : 3.6
250 : 2.8
300 : 2
350 : 1
Ports
Outlet : 2″
Solids passage : ø 40 mm
Berat : Sigle Phase : 12.9 kg
Performance Range
– Flow rate up to 650 l/min (39 m3/h)
– Head up to 14 m
Application Limits
- 5 m maximum immersion depth
( with a sufficiently long power cable) - Maximum liquid temperature +40°C
- Passage of solids
– Up to ø 40 mm for VX/35-N
– Up to ø 50 mm for VX/50-N - Minimum immersion depth for continous service
– 280 mm for VX/35-N
– 300 mm for VX/50-N
Construction and Safety Standard
Power cable length :
– 5 m for VX8-10/35-N, VX8-10/50-N
– 10 mm for VX15/35-N,VX15/50-N
- Float switch for single-phase versions
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60 334-1
CEI 61-150 CEI 2-3
Certifications
Company with management system certified DNV ISO 9001 : Quality
ISO 14001 : Environment
Installation and Use
Vx pump s are recommended for domestic, civil and industrial applications in all cases where the water contains suspended solids up to ø 50 mm, for example groundwater surface waterm filthy and dirty water.
They are for example suitable for draining flooded areas such as cellars, underground car parks, car washes, for emptying cesspools and for sewage disposal.
These pumps distinguish themselves for the their reliability which can be best appreciated under automatic operating conditions in fixed installations.
Patent-Trade-Marks-Models
- Patent pending n. B02015A000116
Options Available On Request
- VX 8-10 pumps with a 10 m power cable
NB : Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor
Applications
- Single-phase pumps without float switch
- Other voltages or 60 Hz frequency