Specification Product :
Single Phase (MCm 10/50-F0), Three Phase (MC 10/50-F)
Power :
KW : 0.75
HP : 1
Flow Rate (Q) = m3/h : Total manometric head = metres
0 : 12
3 : 10.7
6 : 9.7
9 : 8.7
12 : 7.8
15 : 6.8
18 : 5.9
21 : 5
24 : 4
27 : 3
30 : 2
Flow Rate (Q) = l/min : Total manometric head = metres
0 : 12
50 : 10.7
100 : 9.7
150 : 8.7
200 : 7.8
250 : 6.8
300 : 5.9
350 : 5
400 : 4
450 : 3
500 : 2
Ports
Outlet : 2″
Solid passage : ø 50 mm
Berat : Single phase : 14.5 kg
Three phase : 13.2 kg
Performance Range
- Flow rate up to 650 l/min (39 m3/h)
- Head up to 14 m
Application Limits
- 5 m maximum immersion depth
(with a sufficiently long power cable) - Maximum liquid temperature +40°C
- Passage of solids
– Up to ø 40 mm for VX/35-N
– Up to ø 50 mm for VX/50-N - Minimum immersion depth for continous service
– 280 mm for VX/35-N
– 300 mm for VX/50-N - Float switch for single=phase versions
EN 60335-1 EN 60334-1
IEC 60335-1 IEC 60334-1
CEi 61-150 CEI 2-3
Certifications
Company with management system certified DNV ISO 9001 : Quality
ISO 14001 : Environment
Installation and Use
VX pumps are recommended for domestic, civil and industrial application in all cases where the water contains suspended solids up to ø 50 mm, for example groundwater, surface waterm filthy dirty water.
They are for example suitable for draining flooded areas such as cellars, underground car parks, car washer, for emptying cesspools and sewage disposal.
These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
Patents trade mark models
– Patent pending n . B02015A000116
Options Available on Request
– VX 8-10 pumps with a 10 m power cable
NB : Standard EN 60335-2-41 states that the power cable must be 10 m for outdoor
Applications
- Single pase pumps without switch
- Other voltages or 60 Hz frequency