Master Meter SATAM ZCM17 48

The Satam “Master Meter” product range is dedicated to periodic calibration of custody transfer measuring equipment. The ZCM 17 is a working standard that can be used regularly to check and calibrate measuring instruments or measuring systems. With minimal dimensions, it can easily be moved to several different sites without the requirement for lifting tools.
Equipped with an Equalis electronic register that ensures linearization of measurements, it can be used with liquids of various viscosities without loss of accuracy.

 

Sector of application

Oil depots

For oil product reception and loading stations for tank truck, tank car and ships.

Hydrocarbon transportation

Distribution of fuel oil or fuel by road tanker.

Aircraft refuelling

Aircraft dispensers and aircraft fuelling tankers.

Army

Depot supplies and loading of trucks.

Transport companies

Refuelling of locomotives, trucks and public transport coaches.

Marine applications

Refuelling of ships.

Mining sites

Refuelling of trucks or site machinery.

 

Design of the master meter

Robust construction

Positive displacement meter with moving blades.

Modular design

Available with mechanical or electronic register.

Calibration for different viscosities

Supplied with one calibration certificate per each operating viscosity

 

Key points

Compact design

Calibration device of reduced weight and dimensions.

Possibility to move the ZCM 17 to different sites without the requirement for lifting tools

Self powered technology

Functioning of the mechanical register version without any power supply.

Modular design

Wide range of accessories to create your customized calibration device.

Can be installed on a trolley as mobile calibration equipment.

Stability and accuracy of measurements

Stable and accurate volume measurement without any influence of installation position.

Flowmeter manifold separated from measurement chamber to eliminate any possible influence of external mechanical stresses on measurement accuracy.

 

Technical data – Master meter ZCM17  48

Application : Master meter dedicated to calibration of custody transfer volume measuring equipments

Max. Operating flowrate m3/h – L/mn – USGPM : 48 – 800 – 210

Min. Operating flowrate m3/h – L/mn – USGPM : 4.8 – 80 – 21

Measured parameters : Operating volume Base volume (only for ZCM 17 IE)

Measured liquids : Petrol, premium fuels, diesel, E5…E85, bio-diesel, ethanol, methanol, kerosene, fatty acid methyl ester oils

Connections : Flanges or dry couplings*2 x 3 m hoses*

Meter:

Diameter : 2″

PD meter : ZC17-48

 

Versions ZCM 17 IM

Register : Mechanical register (VR). Total volume with reset: 5 digits. Total volume without reset: 8 digits

Volume display : Operating volume

Flowrate display : Included with IDI module L/mn or m3/h

Calibration curve : 7 flowrate values with 2 values per flowrate. One curve per operating viscosity

Calculation of reference volume : Manual calculation

Temperature measurement* : Local display

Pressure measurement* : Local display

Drainage equipment* : Manual drainage pump with purge valve and 2 release valves

Trolley* : Calibration device mounted on chassis with 4 pivoting wheels

Operating conditions :

Pressure : 10 bar max

Viscosity : 50 cSt max.

Liquid temperature : -10 °C to +80 °C

Ambient temperature : Standard : – 25 °C to + 55 °C – Option : – 40 °C to + 55 °C

Metrological performances :

Volume accuracy : < ± 0,1%

Volume repeatability : <± 0,02%

Temperature accuracy : <± 0.5°C

 

Versions ZCM 17 IE

Register : Electronic register (Equalis). Total volume: 6 digits Secure storage of ZCM 17 calibration curves. Calculation of reference volume

Volume display : Operating volume, base volume

Flowrate display : Included

Calibration curve : 7 flowrate values with 2 values per flowrate. One curve per operating viscosity

Calculation of reference volume : Automatic calculation

Temperature measurement* : Pt 100

Pressure measurement* : Local display

Drainage equipment* : Manual drainage pump with purge valve and 2 release valves

Trolley* : Calibration device mounted on chassis with 4 pivoting wheels

Operating conditions :

Pressure : 10 bar max

Viscosity : 50 cSt max.

Liquid temperature : -10 °C to +80 °C

Ambient temperature : Standard : – 25 °C to + 55 °C – Option : – 40 °C to + 55 °C

Metrological performances :

Volume accuracy : < ± 0,05% with linearization

Volume repeatability : <± 0,02%

Temperature accuracy : <± 0.5°C

Leave a Comment

Your email address will not be published. Required fields are marked *