CALIBRATE WOLTMAN FLOW METER LXLC DN 40

Removable element woltman cold water meter
This type of water meter can be used for a remote reading transmission system as equipped with a buit-in sensor.

Application
Measuring the volume of cold water passing through the pipeline

Feature

  • Removable element structure, easy installation and maintenance Register for universal use within this range detechable without removing the meter from the pipeline.
  • Dry-dial, Magnetic drive sensitive action, small pressure loss
  • Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long team service
  • Selected high quality materials for steady & reliable characteristic
  • Technical data conform to international standard IDO 4064

Working Condition

  • Water temperature1℃~50℃ for cold water meter
  • Water pressure PN 10/ 16/ 25
  • Pressure -loss class △p25

Maximum permissible errors

  • From minimum flow-rate (Q1) inclusive to transitional flow-rate (Q2) exclusive ±5%
  • From transitional flow-rate (Q2) to overload flow-rate (Q4) : ±2%

Option Features

  • Copper register
  • Reed switch option
  • Cast Iron

Pulse Position

  • DN 40-65
    Pulse Position : 10/100/1000L/ Pulse
  • DN 80-200
    Pulse Position : 100/ 1000L/ Pulse
  • DN 250-300 :
    Pulse Position : 1000L/ 10000L/ Pulse

Dimension

  • Type : LXLC-40
  • Size : 40
  • L (Length) : 200mm
  • H (Height) : 251 mm
  • Connecting Flange :
    – φ D1 Outside Diameter : 150
    – φ D2 Bolt circle diameter : 125
    – Connecting Bolt (n-M) : 4-M16

Leave a Comment