Main Characteristics :
Fully dry dial meter with no gear reduction in the wet chamber
Wear resistant tungsten carbide/sapphire bearing
Magnetic coupling protected against magnetite
Pulse sender safe from interface
Easy to repair construction with external regulation
DESCRIPTION
The flow sensors AN 130 are multi-jet dry dial vane impeller hot water meters, suitable for installing in central heating and cooling systems and remote warning systems. With their built-in pulse sender they are approved as low sensors for heating meters according the European measuring instruments directive (MID) 2004/22/EG
Versions for horizontal, rising and falling flow directions with screwings (PN 16) or flanges (horizontal flow, PN 25) are available.
TECHNICAL DATA
Display : 00000.000 m³
Working pressure : 16
Working temperature : 10…130℃
Accuracy class : Class 2 or 3
Pulse sender : Reed switch permanently installed
Cable length : 2 m
Load capacity : max.0.1A, max. 28 V
Contact resistance : max 105 Ohm
Pulse value : 10 litres
Casing : Brass, painted
Impeller : Plastic
Impeller Cup : Plastic
Bearing Pin : Tungsten Carbide
Impeller bearing : Sapphire
Magnetic Coupling : Ceramic permanent magnets
PERFORMANCE DATA
Nominal size : 10
Continuous loading : 10 m³/h
Max. Flow rate (short-term) : 20 m³/h
Ratio : 1 : 50
Minimum flow rate : 200 l/h
Pressure loss at : 0.25 bar
Flow rate at 1 bar pressure loss : 20.1 m³/h
DIMENSION AND WEIGHTS
Size marking : 10 m³
Nominal Connection size : 40 mm
Installed length : 300 mm
Height : 197
Flange diameter : 150 mm
Width : 131 mm
Weight : 8 kg