CALIBRATE WOLTMAN FLOW METER TYPE LXLC DN 65 HOT

Application
Measuring the volume of hot water passing through the pipeline

Feature

  • Removable element structure, easy installation and maintenance, register for universal use within this range detachable without removing the meter from the pipeline
  • Dry-dial, magnetic drive sensitive action, small pressure los
  • Vacuum sealed register ensures the dial keep free from fog and keep the reading clear in a long term service
  • Selected high materials for steady & reliable characteristic
  • Technical data conform to international standard ISO 4064

Working Condition

  • Water temperature : 0.1℃~90℃ for hot water meter
  • water pressure : PN10/16/25
  • Pressure-loss clas : △p25

Maximum permissible errors

  • From minimum flow-rate (Q1) inclusive to transitional flow rate (Q2) exclusive ±5%
  • From transitional flow-rate (Q2) to overload flow-rate (Q4) : ±2% hot water meter ±3%

Optional Features

  • Copper register
  • Reed switch option
  • Cast Iron

Pulse Position

  • Size DN 40-65
    Pulse Position : 10/100/1000L/Pulse
  • Size DN 80-200
    Pulse Position : 100/1000L/Pulse
  • Size DN 250-300
    Pulse Position : 1000L/10000L/Pulse

Dimension

  • Type : LXLC 65
  • DN 65
  • L (Length) : 200 mm
  • H (Height) : 271
  • Connecting Flange :
    – φ D1 Outside diameter : 185
    – φ D2 Bolt circle diameter : 145
    – Connecting Bolts (n-M) : 4-M16

Leave a Comment

Your email address will not be published. Required fields are marked *